Designed and developed for modern data centers' requirements for green energy saving, emission reduction, modularization, and intelligent monitoring, they are widely used in financial, government, telecommunications, energy, transportation, medical education, manufacturing and other industries to build, rebuild and expand data centers. Energy efficiency, energy saving up to 30%; strong and weak electrical wiring troughs at the top, closed trajectory opening doors (remote control by remote control card password), fire roof, fire linkage (sound and light alarm, smoke sensor, temperature and humidity sensor), indoor and outdoor units Air conditioners, UPS, rack-mounted precision power distribution cabinets, and data center dedicated cabinets include parallel cabinet components, closed cold aisles, environmental monitoring systems, and KVM.
Modular installation, all installations of the entire system are processed into a modular form to the site through the factory, which is convenient for installation;
The cooling effect is better than the cooling efficiency of a single cabinet, which improves the installation density of the cabinet equipment and saves space in the computer room;
The top cover is opened under the effect of gravity to perform gas fire protection on the cold channel area, which is safe and reliable;
Separate hot and cold air, no turbulence, no short circuit, high refrigeration efficiency, save energy cost;
Comprehensive computer room management, comprehensive dynamic management, accurate energy efficiency analysis, sound security management, standard network management interface, accurate battery management, and convenient management and maintenance.
产品特性 | |
---|---|
通道规格(宽x深x高)mm | 单排:Lx(2200~2400)x(2000~2200),(不含天窗翻转高度)儿<15m(包含空调) 柜体深度支持1000mm、1100mm和1200mm; 柜体高度支持2000mm、2200mm 双排:Lx(3200~3600)x(2000~2200),(不含天窗翻转高度)L<15m(包含空调) 柜体深度支持1000mm、1100mm和1200mm 柜体高度支持2000mm和2200mm 密闭通道宽度支持1200mm和1800mm |
单模组柜体数量 | 单排:3~24;双排:6~40 |
安装方式 | 架空地板安装,也可直接安装在水泥地面上 |
可靠等级 | Tire II或Tier III级以上 |
电源制式 | 380/400/415Vac,50/60Hz,3Ph+N+PE |
系统防护等级 | IP20 |
供配电系统 | |
UPS输入电压 | 380/400/415Vac,50/60Hz,3Ph+N+PE |
UPS额定容量 | 20~250kVA |
UPS配置方式 | N、N+1、2N |
UPS输入功率因数 | 一体式模块化UPS:≥0.9,机架式模块化UPS:1 |
UPS整机效率 | ≥95% |
维护方式 | 在线热插拔维护 |
电池布置方式 | 内置或外置 |
PDU安装方式 | 机柜前部/后部垂直安装 |
IT柜供电方式 | 市电/油机+市电/油机;UPS+UPS;UPS+市电/油机 |
其他 | C级防雷、10英寸显示屏、支路配电参数监测 |
认证情况 | CCC |
制冷系统 | |
空调选型 | 行级风冷/冷冻水、房级风冷/冷冻水 |
制冷方式 | 风冷、冷冻水 |
空调内外机供电方式 | 单独供电 |
空调安装方式 | 室内机架空地板安装,室外机平整水泥地面安装 |
压缩机类型 | 行级:变频压缩机房间级:定频压缩机 |
风机类型 | EC风机 |
送风方式 | 行级:水平送风房间级:下送风 |
空调室內机尺寸(宽x深ⅹ高)mm | 行级空调:300×1200×2000600×1200×2000房间级空调详见选型表 |
认证情况 | CQC节能 |
监控管理系统 | |
功能模块 | 集中管理、门禁管理、视频监控、资产管理、电池监测 |
访问方式 | 运程web访问、本地10英寸触摸屏、手机APP(选配) |
报警方式 | 微信报警、本地声光报价、短信报警、邮件报警、电话报警 |
认证情况 | 软件著作权、软件测试报告 |
机柜系统 | |
尺寸规格(宽x深x高)mm | (600/800)x(1000/1100/1200)x(2000/2200) |
可用空间 | 42U/47U |
认证情况 | 抗震报告、承重报告 |